IoT Long Range Wireless Pressure Sensor Bidirectional Differential
Highlights
- Industrial Grade Bidirectional Differential Pressure Sensor with Temperature Output
- 4 User Selected Operating Pressure Ranges During Checkout
- Pressure Resolution up to 0.01 PSI (Depending on Sensor Option)
- Operating Temperature Range -20° to +70° C
- Temperature Resolution 0.01°C
- 2 Mile Range with 900MHz On-Board Antenna
- Superior LOS Range of up to 28 miles with 900MHz High-Gain Antennas
- Interface to Raspberry Pi, Microsoft Azure, Arduino and More
- Example Software for Visual Studio and LabVIEW
- Wireless Mesh Networking using DigiMesh®
- Open Communication Protocol for Custom Interfacing Applications
- Secure Transmission using AES-128 Encryption
IoT Long Range Wireless Pressure Sensor – Bidirectional Differential
Introducing NCD’s IoT Long range Wireless Bidirectional Differential Pressure Sensor with integrated temperature sensor. With an incredible 2 Mile wireless range, this IoT pressure sensor uses a 900MHz wireless mesh networking architecture to hop data across large networks when longer range is required. Incorporating a AMS5812 series high-resolution medical grade pressure sensor, this IoT pressure sensor samples pressure and temperature data, then transmits these data to user defined receiver(s). The whole process is repeated at user-defined intervals. For technical details on the pressure sensing element, please refer to the AMS5812 datasheet. This Wireless Bidirectional Differential Pressure Sensor comes with Two nozzles and Silicone Rubber Tubing.
Includes 2 Pieces of Silicone Rubber Tubing: 4mm O.D. x 2.5mm I.D. x .5 Meter Length. Please contact us if other lengths are required.
Sensor Options during Checkout:
AMS5812-0150-D-B Amplified Pressure Sensor -1034 to +1034 mbar -15 to +15 PSI
AMS5812-0050-D-B Amplified Pressure Sensor -344.7 to +344.7 mbar -5 to +5 PSI
AMS5812-0001-D-B Amplified Ultra Low Pressure Sensor -10.34 to +10.34 mbar -0.150 to +0.150 PSI
AMS5812-0003-D-B Amplified Low Pressure Sensor -20.68 to +20.68 mbar -0.30 to +0.30 PSI
Special Order Option (See Device Compatibility Tab for a Complete List of Special Order Sensors)
Transmission Interval
This device sends data periodically, based on user-preset timing intervals.
Wireless Pressure Sensor Applications
- Wireless Differential Pressure Monitoring
- Fluid level Monitoring
- Medical Instrumentation
- Heating, Ventilation and Air Conditioning (HVAC)
- Component of a Low Power IoT System
- Home Automation and Control
- Water Tank Level Measurement
- Wireless Bidirectional Differential Pressure Monitoring for Raspberry Pi/Arduino
- Wireless Bidirectional Differential Pressure Monitoring for AWS/Azure
Mechanical Drawing
Wiring Diagrams
Essential
Datasheets
Documentation Downloads
Community Repositories
Enterprise 868 MHz Sensors
Enterprise 900MHz Sensors
Not for use in outdoor applications. Includes industrial batteries rated for Operating Temperature Range -20° to +70° C. Standard Alkaline batteries may prevent operation during prolonged freezing temperatures. Prolonged exposure to extreme humidity conditions may damage this device. The sensing element is rated for use for 5 years and may be replaced. NCD Warranty does not cover battery corrosion or use in excessively smoky environments under any circumstances.
Includes 4mm O.D. x 2.5mm I.D. x .5 Meter Length Silicone Rubber Tubing. Please contact us if other lengths are required.
Sensor Options during Checkout:
AMS5812-0150-D-B Amplified Pressure Sensor -1034 to +1034 mbar -15 to +15 PSI
AMS5812-0050-D-B Amplified Pressure Sensor -344.7 to +344.7 mbar -5 to +5 PSI
AMS5812-0001-D-B Amplified Ultra Low Pressure Sensor -10.34 to +10.34 mbar -0.150 to +0.150 PSI
AMS5812-0003-D-B Amplified Low Pressure Sensor -20.68 to +20.68 mbar -0.30 to +0.30 PSI
This device is available with the following AMS Pressure Sensors by Special Order, Please Contact Us and copy the desired option into the order notes field during checkout:
AMS5812-0015-D Amplified Low Pressure Sensor 0-103.4 mbar 0 to 1.50 PSI
AMS5812-0300-A Amplified Absolute Pressure Sensor 0 to 2068 mbar 0 to 30 PSI
AMS5812-0150-B Barometric Pressure Sensor 758.4 to 1206 mbar 11 to 17.5 PSI
AMS5812-0600-D Amplified Pressure Sensor 0-4137 mbar 0 to 60.0 PSI
AMS5812-0300-D Amplified Pressure Sensor 0-2068 mbar 0 to 30.0 PSI
AMS5812-0050-D Amplified Pressure Sensor 0-344.7 mbar 0 to 5 PSI
AMS5812-0001-D Amplified Ultra Low Pressure Sensor 0-10.34 mbar 0 to 0.150 PSI
AMS5812-0008-D Low Pressure Sensor 0-55.16 mbar 0 to 0.80 PSI
AMS5812-0150-A Amplified Absolute Pressure Sensor 0 to 1034 mbar 0 to 15 PSI
AMS5812-0030-D-B Amplified Pressure Sensor -206.8 to +206.8 mbar -3 to +3 PSI
AMS5812-0015-D-B Amplified Low Pressure Sensor -103.4 to +103.4 mbar -1.50 to +1.50 PSI
AMS5812-0000-D-B Amplified Ultra Low Pressure Sensor -5.17 to +5.17 mbar -0.075 to +0.075 PSI
AMS5812-0008-D-B Amplified Low Pressure Sensor -55.16 to +55.16 mbar -0.80 to +0.80 PSI
AMS5812-0030-D Amplified Pressure Sensor 0-206.8 mbar 0 to 3.0 PSI
AMS5812-1000-D Amplified Pressure Sensor 0-6895 mbar 0 to 100.0 PSI
AMS5812-0150-D Amplified Pressure Sensor 0-1034 mbar 0 to 15.0 PSI
AMS5812-0003-D Amplified Low Pressure Sensor 0-20.68 mbar 0 to 0.30 PSI
AMS5812-0000-D Amplified Ultra Low Pressure Sensor 0-5.17 mbar 0 to 0.0725 PSI
900HP-S3B Wireless Compatibility Notes
Notice: Compatibility Notes Does NOT Apply to the Following Products:
- NCD Enterprise Solutions
- NCD Wireless Sensors
- NCD Enterprise Modems and Gateways
Notice: Compatibility Notes Applies to NCD Industrial Products, Including Fusion, ProXR, ProXR Lite, Taralist, and Reactor Series Products.
Compatibility Notes
When using an 900HP-S3B communication module, it is essential that you use the ZIGMO_PCB to configure the module settings. Long-Range wireless sensors may be programmed over the air without removing the communications module.
A 900HP-S3B Modem or a gateway of some kind that support the 900HP-S3B communications module will also be required.