Wireless Thermocouple High Temperature Sensor C1D2 Certified for Hazardous Environments
Highlights
- C1D2 Certified Temperature Sensor for Hazardous Locations
- Group A, B, C, and D Certification
- Industrial Long Range Wireless Thermocouple Transmitter
- K type thermocouple Connector
- Wall-Mounted or Magnet Mounted IP65 Rated Enclosure
- Up to 2 Mile Line-of-Sight Range with Integrated Antenna
- Wireless Mesh Networking using DigiMesh® 900MHz
- Open Communication Protocol for Easy Software Integration
- Small 3″ x 3″ Form Factor Wireless IoT Thermocouple Sensor
- Power-Efficient Sleep Mode, Up to 10 Year Battery Life
- User Configurable Sleep duration
- Up to 500,000 Transmissions from 6 AA Batteries
- Includes Battery Level with Every Transmission
- Validates and Retries Lost Communication Packets
Industrial Wireless Thermocouple High Temperature Sensor for Hazardous Environments
NCD’s new C1D2 certified long range wireless Thermocouple Temperature sensors offer the an industry first for long range wireless IoT sensors designed specifically for use in hazardous environments. With C1D2 Group A, B, C, and D certification, this long range wireless Thermocouple Temperature sensor is specified for use in hazardous environments where potentially explosive gasses, dust, fibers, or flammable vapors may be present. This includes hazardous gases and vapors that may contain Acetylene, Hydrogen, Ether, Ethyl, Ethelene, Gasoline, Acetone, Ammonia, Benzene, Butane, Methanol, and Propane. NCD’s C1D2 certified sensors are the only long range wireless products available on the market today that may be used in chemical plants, oil and gas refineries, paint shops, cleaning facilities, mills, flour silos, mining, and loading facilities for flammable gases, liquids, and solids.
With an integrated antenna and up to a 2-mile range using a wireless mesh networking architecture, this sensor incorporates a 900MHz 128-Bit AES encrypted transceiver that sends data at user-defined intervals over long distances to a wireless gateway. This IoT Thermocouple Temperature Sensor goes to sleep between transmissions to minimize power consumption and prolong battery life. Incorporating a high resolution Temperature sensor, this sensor transmits highly accurate temperature data every 10 minutes with the default settings. Between transmissions, this sensor will go to sleep, extending the life of the batteries. Up to 10 years of battery life may be achieved depending on environmental conditions and the transmission interval you choose.
NCD Industrial wireless thermocouple High Temperature sensor is capable of measuring extreme high and low temperatures. This sensor includes integrated hot and cold junction to provide highly accurate readings. This Industrial wireless thermocouple transmitter is ideal for high temperature measurements, industrial boiler temperature measurements, liquid temperature measurement, and temperature monitoring of food storage units. This Industrial wireless thermocouple sensor is designed to consume extremely low power and send data at extremely long distances of up to 2 miles with an integrated antenna. Powered by just 6 AA batteries with a operational lifetime of 500,000 wireless transmissions, you can expect to achieve up to 10 years of battery life depending on environmental conditions and the transmission interval you choose.
The NCD Long Range Industrial Wireless IoT Thermocouple Temperature Sensor has one of the longest ranges, highest accuracies, longest battery life, and best security features on the market today. NCD is the only manufacturer of a complete ecosystem of C1D2 certified long range wireless sensors with an open protocol for integration into any software system. To help get you started, use a NCD Gateway running Node-RED to receive and decode the long range wireless transmissions generated by this sensor. Use Node-RED to patch into any cloud platform with minimal programming. Communicate to your own MQTT server or use a common IoT platform such as AWS® and Microsoft Azure®. Node-RED offers the flexibility to handle just about any cloud platform imaginable or keep your data on your own server without using a 3rd party ecosystem. NCD wireless sensor protocols allow you to keep data secure and private or integrate with any cloud platform of your choice!
Thermocouple Ratings
Wire Gage: 20 gage solid–standard limits of error
Insulation: Nextel® ceramic fiber
Overbraiding & Fittings: Inconel 600®
Temperature: 980°C (1800°F) continuous, 1090°C ( 2000°F) short-term service, depending on thermocouple type.
Termination: Ceramic beaded leads with compensated spade lugs, OMEGA™ OSTW 220°C (425°F) male connector, or OMEGA™ NHXH high temperature 650°C (1200°F) ceramic male connector
High Temperature Sensor Applications
- Food Storage Temperature Monitoring
- HVAC High-Side Low-Side Temperature Monitoring
- Industrial Boiler Temperature Measurements
- Liquid Temperature Measurement
- Oven Temperature Monitoring
- Concrete Temperature Monitoring
What is Class 1 Division 2 Certification?
Class 1, Division 2 is a hazardous location rating system that indicates where flammable gases, vapors, or combustible dust may be present. It also specifies the types of technology that are safe to use in these environments. Class 1, Division 2 locations are places where flammable liquids or gases are used, processed, or handled. These liquids or gases are usually kept in closed systems or containers, and can only escape if the systems or containers deteriorate or rupture. Under normal operating conditions, a Class 1, Division 2 location shouldn’t have an explosive atmosphere, but it may occur briefly during maintenance or repair activities, or if a container or vessel accidentally ruptures.
Class 1, Division 2 equipment must meet strict hazardous location rating requirements to ensure it can safely operate in these environments. This compliance can help improve workplace safety and reduce the risk of accidents. Select NCD sensors are Class 1, Division 2 certified for hazardous environments and can prevent ignition in atmospheres that may contain explosive gases or vapors.
NCD C1D2 Certified Sensors are certified for use in groups A, B, C, and D. A list of groups and their associated environments are listed below.
Group A contains only acetylene.
Group B includes hydrogen, gases with more than 30% hydrogen by volume, butadiene, ethylene oxide and propylene oxide.
Group C includes acetaldehyde, cyclopropane, diethyl ether, and dimethyl hydrazine.
Group D includes gasoline, acetone, ammonia, benzene, butane, methane, propane, alcohols and other more commonly encountered compounds.
Who Requires C1D2 Certification?
- Chemical plants
- Oil and gas refineries
- Paint shops
- Cleaning facilities
- Mills
- Flour silos
- Mining
- Loading facilities for flammable gases, liquids, and solids
- Glue factories
- Oil rigs
- Oil pipelines
IoT Vibration Sensor Applications
- Hazardous Location Long Range Temperature Vibration Sensor
- C1D2 Certified for Use in Hazardous Environments
- Factory Floor Temperature and Vibration Monitoring
- Oil and Gas Industrial Vibration Monitoring
- Factory Machine Vibration Monitoring System
- Motor Temperature Vibration Monitoring System
- Wireless Temperature Vibration Sensor for Machine Monitoring
- Temperature Vibration Sensor For Device Control Application
- For Use with NCD Long Range Wireless Gateways
- Wireless Temperature Vibration Monitoring for AWS® and Azure®
Mechanical Drawing
Wiring Diagrams
Essential
Documentation Downloads
C1D2 Certification Documents for NCD Long Range Wireless Sensors
Not for use in outdoor applications or for use in excessive temperature conditions. Prolonged freezing will prevent batteries from functioning until thawed, using extended temperature range industrial batteries may improve the useful temperature range. Extended freezing applications should use a full-time powered solution. Prolonged exposure to extreme humidity conditions may damage this device. The sensing element is rated for use for 5 years and may be replaced. Exposure to high temperatures may cause the batteries to leak, causing permanent damage to this device. NCD Warranty does not cover battery corrosion or use in excessively smoky environments under any circumstances.
Tested and verified for use with NCD Micro Gateway Products.
900HP-S3B Wireless Compatibility Notes
Notice: Compatibility Notes Does NOT Apply to the Following Products:
- NCD Enterprise Solutions
- NCD Wireless Sensors
- NCD Enterprise Modems and Gateways
Notice: Compatibility Notes Applies to NCD Industrial Products, Including Fusion, ProXR, ProXR Lite, Taralist, and Reactor Series Products.
Compatibility Notes
When using an 900HP-S3B communication module, it is essential that you use the ZIGMO_PCB to configure the module settings. Long-Range wireless sensors may be programmed over the air without removing the communications module.
A 900HP-S3B Modem or a gateway of some kind that support the 900HP-S3B communications module will also be required.
1 in stock